Description
Features
Built in Temperature meter
Two Identical Single Phase Transformer
Equipped with supply indication lamps
Designed by considering all the safety standards
Diagrammatic representation for the ease of connections
Flexibility to configure Step – up to Step – down and isolation transformer
Learning’s
1. Study of the Polarity Test of Two Single Phase Transformers
2. Study of Sumpner’s Test by:
A . Open Circuit Test of Transformer
B. Short Circuit Test of Transformer
3. Calculation of Efficiency and regulation of Two Single Phase Transformers







Reviews
There are no reviews yet.